Littelfuse SE-330AU-26-01 NGR Monitor 48VDC Dual RJ45 IEC 61850 NC
$5,171$6,205 (-17%)
Littelfuse SE-330AU-26-01 Neutral Grounding Resistor (NGR) monitor — 28–52 VAC / 36–72 VDC supply, IEC 61850 Dual RJ45 and USB communications. Genuine Littelfuse protection relay, available from Batam with fast delivery across Indonesia & Southeast Asia.
The Littelfuse SE-330AU-26-01 is a neutral grounding resistor (NGR) monitor and earth-fault protection relay designed for low- and medium-voltage transformers, generators and distribution systems. With 28–52 V AC or 36–72 V DC supply options, IEC 61850 (dual RJ45) and USB communications, it continuously monitors neutral current, neutral-to-earth voltage and resistance, providing configurable ground-fault trip levels and 4–20 mA analogue output for system integration.
Key Features
- Multiple contact options: selectable 1 Form A (NO), 1 Form B (NC) or 2 Form C (changeover) relay outputs for alarm/trip.
- Wide supply compatibility: supports 28–52 V AC and 36–72 V DC control supplies for flexible installation.
- Advanced fault detection: ground-fault trip range 0.125–30.0 A with trip times from 0.1 to 0.5 seconds.
- Residual/fault voltage detection: RF trip thresholds 20–2000 V (systems ≤5 kV) or 100–10000 V (systems >5 kV).
- Communications and outputs: IEC 61850 (dual RJ45) and USB ports plus 4–20 mA analogue output for monitoring and SCADA integration.
- Reset and filtering: front-panel or remote N.O. reset, with standard harmonic filtering to reduce nuisance trips.
Technical Specifications
| Manufacturer | Littelfuse |
|---|---|
| Commercial Reference | SE-330AU-26-01 |
| Component | Neutral Grounding Resistor Monitor (NGR monitor / earth-fault relay) |
| Supply Voltage (AC) | 28–52 V AC |
| Supply Voltage (DC) | 36–72 V DC |
| Contact Configurations | 1 Form A, 1 Form B, or 2 Form C (selectable) |
| Ground-fault Trip Range | 0.125–30.0 A |
| Ground-fault Trip Time | 0.1–0.5 seconds |
| Residual/Fault (RF) Trip Voltage | 20–2000 V (systems ≤5 kV); 100–10000 V (systems >5 kV) |
| Analogue Output | 4–20 mA |
| Communications | IEC 61850 (Dual RJ45), USB |
| Reset | Front-panel switch or remote N.O. contact |
| Monitoring Functions | Neutral current, neutral-to-earth voltage, neutral-to-earth resistance; continuous verification of NER integrity |
| Revision | New revision available (old revision discontinued) |
Applications
Used for neutral earthing resistor monitoring and ground-fault protection on transformers, generator neutrals, MV distribution panels and industrial power systems in utilities, manufacturing, mining and petrochemical plants.