No products in the cart.
Dwyer SBLT2-240M-250M Submersible Level Transmitter
$2,337$2,804 (-17%)
Dwyer SBLT2-240M-250M is a submersible level transmitter suitable for measuring liquid levels in tanks. It has a temperature range of 0 to 150°F (-18 to 66°C) for polyurethane and 0 to 200°F (-18 to 93°C) for ETFE. The accuracy is ±0.25% FS and it requires a power supply of 10 to 30 VDC. The response time is 50 ms and…
Dwyer SBLT2-240M-250M is a submersible level transmitter suitable for measuring liquid levels in tanks. It has a temperature range of 0 to 150°F (-18 to 66°C) for polyurethane and 0 to 200°F (-18 to 93°C) for ETFE. The accuracy is ±0.25% FS and it requires a power supply of 10 to 30 VDC. The response time is 50 ms and it provides a 4 to 20 mA DC output signal. It is designed to be mounted below the level being measured and is made of 316 SS and 316L SS materials. It can withstand a pressure of 2X FS and has a thermal effect of ±0.02% full scale per degree Fahrenheit. The electrical connection is via a wire pigtail and it is compatible with various liquids.
Specifications
| Component | Submersible Level Transmitter |
|---|---|
| (Instrument-Sensor) Measurement Accuracy | 0.25% |
| (Instrument-Sensor) Application | Liquid |
| Manufacturer | Dwyer Instruments |
| (Instrument – Sensor) Supply Voltage | 10 – 28 VDC |
| (Instrument – Sensor) Supply Voltage | 10 – 30 VDC |
| (Instrument-Sensor) Temperature Range | -4 – 176 °F/-20 – 80°C |
| (Instrument-Sensor) Temperature Range | 0 – 200 °F/-18 – 93°C |
| (Instrument-Sensor) Temperature Range | -4 – 149 °F/-20 – 65°C |
| (Instrument-Sensor) Temperature Range | 0 – 150 °F/-18 – 66°C |
Features
Slim design for tight applications with bullet nose, which protects the diaphragm from damage
Incorporates lightning and surge protection utilizing dual arrestor technology, grounded to case, eliminating both power supply surges and lightning ground strike transients (surge protection is not guaranteed and is not covered by warranty) on SBLT2 models
Maintenance free filter eliminates particulate or water droplets from entering and damaging the transducer
UL approved intrinsically safe on SBLTX models for use in hazardous locations when used with proper barrier
Excellent chemical compatibility for wide application use
NPT connection allows the unit to be rigidly installed in a pipe/conduit, or the addition of a A-625 hanging loop for attaching a chain for pulling out of the installation
Standard 72 hour lead time ensures minimal downtime









Reviews
There are no reviews yet.